Last reviewed 2026-10-11. Journalists, researchers, and community groups are welcome to cite any figure on this page with attribution and a link.
This page sets out the weather, code, ground and housing figures behind concrete work in Yonkers, each with its source and vintage. Weather comes from NOAA's 1991-2020 normals for the Dobbs Ferry-Ardsley station, north of the city, beside White Plains at Westchester County Airport and Central Park in New York City, shown only for comparison: Yonkers is its own city in Westchester County, under New York's Uniform Code and its own City code. Code values come from the New York State Department of State and the concrete table of the model International Residential Code; pouring limits from the National Ready Mixed Concrete Association (NRMCA) and the American Concrete Institute (ACI); ground data from USDA NRCS, the U.S. Geological Survey and the State's environmental agency; housing counts from the ACS 2024 5-year estimates of the Census Bureau.
We work from the same figures. For outdoor concrete we order an air-entrained mix at the strength New York's residential code requires in a severe weathering region, we do not pour on frozen ground, and in cold weather we protect fresh concrete as NRMCA's CIP 27 (1998, 2014) describes. Because NRMCA's CIP 2 on scaling (revised 2014) advises against deicing chemicals in the first winter, we ask you to keep salt off new work that season. This page carries no prices: published ranges with their survey dates are on our Yonkers concrete cost page, and the City's permit, sidewalk and snow rules are in our Yonkers permits and sidewalk rules guide.
108.9
Days a year that reach a low of 32 degrees F or below at Dobbs Ferry-Ardsley
NOAA 1991-2020 normals
April 20 and October 26
Even-odds dates for the last spring and first fall 32 degrees F freeze at Dobbs Ferry-Ardsley
NOAA 1991-2020 normals
About 25 degrees F
Concrete temperature below which fresh concrete freezes
NRMCA CIP 27, 1998 and 2014
3,500 psi
Minimum strength for weather-exposed porches, steps, carport slabs and garage floors in a severe weathering region
2009 IRC Table R402.2, reprinted by Penn State PHRC
42 inches
Frost line depth printed by Harrison and Croton-on-Hudson; the Yonkers entry is read as 3 feet 6 inches, foot mark unconfirmed
Harrison, Croton-on-Hudson and Yonkers climatic design tables
1958
Median year built of Yonkers housing units
Census Bureau ACS 2024 5-year, table B25035
Winter in numbers: Dobbs Ferry-Ardsley, White Plains and Central Park
At Dobbs Ferry-Ardsley (station USC00302129), NOAA's 1991-2020 normals average 108.9 days a year when the thermometer drops to 32 degrees F or lower, and 13.8 days whose high also fails to climb above freezing. Monthly means run from 31.4 in January to 75.0 in July, and January's normal daily low is 23.1, with a high of 39.8; NOAA's documentation for the 1991-2020 normals gives these temperatures in degrees F to the nearest tenth. Precipitation averages 51.24 inches a year; the snowfall normal is 32.7 a year and 25.9 for December through February, both in inches. NOAA states its freeze dates as 50 percent probability dates: April 20 for the last 32-degree freeze of spring and October 26 for the first one of fall.
White Plains, at Westchester County Airport (USW00094745), has a colder January mean of 29.8 (degrees F); there, days whose minimum is 32 degrees F or lower average 104.7 a year, 23.0 of them with a maximum no higher than freezing. NOAA's 1991-2020 response for that station has no snowfall normal. Central Park (USW00094728) is in New York City, south of Yonkers, and serves only as a comparison: NOAA counts 67.3 such days a year there. On Yonkers streets, the City's Department of Public Works maintains 654 lane miles of roads and spreads salt at 300 pounds or more per lane mile (Snow and Ice Control page, no date shown). NRMCA's CIP 2 (revised 2014) counts rock salt and calcium chloride as acceptable deicers for concrete and warns against ammonium sulfate, ammonium nitrate and magnesium-based salts.
| 1991-2020 normal | Dobbs Ferry-Ardsley | White Plains (Westchester Co. Airport) | Central Park (New York City) |
|---|---|---|---|
| Mean temperature, January (degrees F) | 31.4 | 29.8 | 33.7 |
| Mean temperature, July (degrees F) | 75.0 | 74.0 | 77.5 |
| Mean temperature, year (degrees F) | 53.4 | 52.0 | 55.8 |
| Precipitation, year (inches) | 51.24 | 47.75 | 49.52 |
| Snowfall, year (inches) | 32.7 | No normal in NOAA's response | 29.8 |
| Days with a low at or below 32 degrees F | 108.9 | 104.7 | 67.3 |
| Days with a high at or below 32 degrees F | 13.8 | 23.0 | 16.0 |
| Last spring freeze, 32 degrees F (50 percent date) | Apr 20 | Apr 12 | Mar 30 |
| First fall freeze, 32 degrees F (50 percent date) | Oct 26 | Oct 31 | Nov 20 |
| Freeze-free season (days) | 189.0 | 200.0 | 236.0 |
Source: NOAA NCEI U.S. Climate Normals, 1991-2020 (annual/seasonal and monthly), stations USC00302129, USW00094745 and USW00094728. Freeze dates are NOAA's 50 percent probability dates. Central Park is in New York City and appears only for comparison; NOAA's normals response for White Plains has no snowfall normal.
What New York's code sets for concrete in a severe weathering region
Bulletin TB-1009-RCNYS from New York's Department of State, written for the State's 2020 residential code, assigns every part of the State to the "Severe" weathering category and notes that, under section R402.2, weathering bears on concrete's compressive strength and air entrainment. The State's code is based on the model International Residential Code, and Table R402.2 of its 2009 edition, reprinted by Penn State's housing research center in 2016, lists 3,500 psi in its severe column for porches, carport slabs and steps exposed to the weather and for garage floors, 3,000 psi for walls and other vertical work exposed to the weather, and 2,500 psi for foundations and interior slabs kept out of it. Footnote d requires the concrete to be air-entrained, at a total air content between 5 and 7 percent. Since December 31, 2025, permit applications have had to meet the State's 2025 Uniform Code.
Frost depth is a local number: TB-1009-RCNYS leaves it to each local jurisdiction to set how deep a footing must sit below finish grade, and the Department of State's 2025 plan review handbook (9E25, version 8/10/2026) checks footing depth under section R403.1.4 against that local table. The frost cell in the City of Yonkers' Table R301.2(1), revised 12/28/2020, is read in context as 3 feet 6 inches, but its foot mark could not be confirmed, so check it with the City's Department of Housing and Buildings; Harrison and Croton-on-Hudson print 42 inches. The handbook also sets a 3-1/2 inch minimum for floors on ground (section R506) and, for stairs, risers no taller than 8-1/4 inches and treads at least 9 inches deep (section R318.7.5). Our foundations and footings page shows how the frost line sets a footing.
| Item | Value | Source |
|---|---|---|
| Weathering potential | Severe statewide; the Yonkers table prints SEVERE | DOS TB-1009-RCNYS; Yonkers Table R301.2(1) |
| Porches, carport slabs and steps exposed to weather; garage floors | 3,500 psi | 2009 IRC Table R402.2 via Penn State PHRC |
| Walls and other vertical concrete exposed to weather | 3,000 psi | Same table |
| Foundations, basement walls and interior slabs not exposed | 2,500 psi | Same table |
| Air entrainment (footnote d) | Air-entrained; total air 5 to 7 percent | Same table |
| Steel-troweled garage floor (footnote f) | Air may drop to 3 percent if strength is at least 4,000 psi | Same table |
| Frost line depth, Yonkers | Reads as 3 feet 6 inches; foot mark unconfirmed | Yonkers Table R301.2(1), rev. 12/28/2020 |
| Frost line depth, Harrison and Croton-on-Hudson | 42 inches | Their climatic design tables |
| Air freezing index, Yonkers | 1500 | Yonkers Table R301.2(1) |
| Concrete floor on ground | 3-1/2 inches minimum; strength per R402.2 | DOS 9E25 handbook, section R506 |
| Base course under a slab | 4 inches granular where below grade; not required on well-drained soils (Group I) | DOS 9E25 handbook, section R506 |
| Vapor retarder under a slab | 6 mil poly or approved alternate | DOS 9E25 handbook, section R506 |
| Stair riser and tread | 8-1/4 inches maximum; 9 inches minimum | DOS 9E25 handbook, section R318.7.5 |
| Handrails and guards | Handrails 34 to 38 inches high; guards at least 36 inches where a surface is over 30 inches up (two stair exceptions) | DOS 9E25 handbook |
Sources and editions: Department of State bulletin TB-1009-RCNYS (2020 Residential Code of New York State) and its 9E25 plan review handbook (version 8/10/2026, 2025 code); the model code behind the State's code, the International Residential Code, whose 2009 Table R402.2 Penn State's PHRC reprinted (12/12/2016); the climatic tables of the City of Yonkers (revision 12/28/2020), Harrison (page dated 9/28/07) and Croton-on-Hudson (effective 5/12/2020). Confirm the frost depth with the City's Department of Housing and Buildings.
Cold- and hot-weather pouring, month by month at Dobbs Ferry-Ardsley
NRMCA's CIP 27 on cold weather concreting (1998, 2014) defines cold weather as an average daily temperature below 40 degrees F for more than 3 days in a row, with the air at or below 50 degrees F for more than half of any 24-hour period. It says fresh concrete freezes below about 25 degrees F, that freezing can cut its potential strength by more than 50%, and that it needs protection until it reaches 500 psi, about two days after placement; sections under 12 inches thick go in at 55 degrees F or more. ACI's FAQ says hydration slows sharply below 40 degrees F and that from 40 to 60 degrees F a longer moist cure gives satisfactory results. In NOAA's 1991-2020 Dobbs Ferry-Ardsley normals, December through February average under 40 degrees F, and each month from October through May averages some lows of 32 degrees F or colder.
Heat works the other way. NRMCA's CIP 12 on hot weather concreting (dated 1982 to 2014) says high concrete temperature raises water demand, speeds slump loss and shortens setting time, and it advises placing and finishing outside the hottest part of the day and curing for at least 3 days. ACI 301-20 and ACI 305.1-14 cap the concrete temperature at 95 degrees F at discharge. In the Dobbs Ferry-Ardsley normals, June through August are the warmest months, July's normal daily high is 85.6 (degrees F), and highs of 90 degrees F or more average 18.6 a year. If you are picking a pour date for a new concrete driveway, the table lines up each month with those limits.
| Month | Mean (degrees F) | Days with a low at or below 32 degrees F | Snowfall (inches) | Mean against the guidance lines |
|---|---|---|---|---|
| January | 31.4 | 25.8 | 9.4 | Below 40 (CIP 27 cold-weather line) |
| February | 33.7 | 22.9 | 10.9 | Below 40 (CIP 27 cold-weather line) |
| March | 40.9 | 18.2 | 5.8 | 40 to 60 (ACI: lengthen moist curing) |
| April | 51.4 | 5.7 | 0.7 | 40 to 60 (ACI: lengthen moist curing) |
| May | 61.3 | 0.4 | 0.0 | Above 60 |
| June | 69.8 | 0.0 | 0.0 | Above 60; hot-day steps (CIP 12) |
| July | 75.0 | 0.0 | 0.0 | Above 60; hot-day steps (CIP 12) |
| August | 73.5 | 0.0 | 0.0 | Above 60; hot-day steps (CIP 12) |
| September | 66.5 | 0.0 | 0.0 | Above 60 |
| October | 55.3 | 2.4 | 0.0 | 40 to 60 (ACI: lengthen moist curing) |
| November | 45.2 | 11.4 | 0.3 | 40 to 60 (ACI: lengthen moist curing) |
| December | 36.6 | 22.1 | 5.6 | Below 40 (CIP 27 cold-weather line) |
Sources: NOAA NCEI monthly normals, 1991-2020, Dobbs Ferry-Ardsley (USC00302129); NRMCA CIP 27 (1998, 2014) and CIP 12 (1982 to 2014); ACI technical FAQ on temperature and curing. The last column compares each monthly mean with CIP 27's 40 degrees F line and ACI's 40 to 60 degrees F band; daily temperatures swing above and below the mean.
The ground under Yonkers: soil map units, bedrock and high water
USDA NRCS soil maps for Westchester County (survey area NY119) put the Census Bureau's internal point for Yonkers on UpB, an Urban land-Paxton complex on 3 to 8 percent slopes, and map plain Urban land downtown, which NRCS leaves unrated for engineering uses. In the northwest, central-west and east the maps show Urban land-Charlton-Chatfield complexes listed as rolling or hilly and very rocky. NRCS's Charlton series description (revised 05/2016) puts bedrock commonly more than 180 cm down, while Chatfield soils (revised 04/2017) reach it at 50 to 100 cm. NRCS rates UpB, UpC and the very rocky Charlton-Chatfield complex CrC as very limited for local roads and streets. The U.S. Geological Survey's State Geologic Map Compilation shows Fordham Gneiss at every point sampled except one in the southeast, where it shows Yonkers Gneiss; our retaining walls page covers the City's steep-slope rules.
Water is the other ground question. In NRCS's sample box inside the city, Leicester loam (LcB) is somewhat poorly drained, and the stream-bottom Fluvaquents-Udifluvents complex (Ff) is poorly drained and rated for frequent flooding. The U.S. EPA says the Saw Mill River downtown was buried in the 1920s for flood mitigation (fact sheet, February 2021). The State Department of Environmental Conservation's flood project fact sheet describes a U-shaped channel on the Saw Mill that the City operates and maintains: work began August 9, 1967, was operationally complete in November 1968, and the design "stream discharge of 1,450 cubic feet" was then 42 percent greater than the largest flood on record. FEMA flood zones are not among the sources on this page.
| Unit or rock | Where | What the source gives |
|---|---|---|
| UpB Urban land-Paxton complex, 3 to 8 percent slopes | Census internal point of Yonkers | Well drained; very limited for local roads; not limited for basements |
| UpC Urban land-Paxton complex, 8 to 15 percent slopes | NRCS sample box | Well drained; very limited for local roads |
| Uf Urban land | Downtown and southeast points | Not rated for engineering uses |
| UlC and UlD Urban land-Charlton-Chatfield complexes, very rocky | Northwest (UlC); central-west and east (UlD) | Rock: Charlton commonly more than 180 cm down, Chatfield 50 to 100 cm |
| CrC Charlton-Chatfield complex, 0 to 15 percent slopes, very rocky | NRCS sample box | Well drained; flooding none; very limited for roads and basements |
| UwB Urban land-Woodbridge complex, 3 to 8 percent slopes | NRCS sample box | Moderately well drained; very limited for local roads |
| UvC Urban land-Riverhead complex, 8 to 15 percent slopes | NRCS sample box | Listed; no ratings recorded |
| LcB Leicester loam, 3 to 8 percent slopes, stony | NRCS sample box | Somewhat poorly drained; very limited for dwellings and roads |
| Ff Fluvaquents-Udifluvents complex, frequently flooded | NRCS sample box (stream bottom) | Poorly drained; flooding frequent; water-table field 0 |
| Fordham Gneiss, undivided (bedrock) | Internal point, downtown, central-west, northwest, east, south | Gneiss and amphibolite; Mesoproterozoic |
| Yonkers Gneiss (bedrock) | Southeast point | Biotite and/or hornblende-quartz-feldspar gneiss |
| Saw Mill River flood channel | 8,722 feet of the Saw Mill River | U-shaped channel; work 1967 to 1968; operated by the City |
Sources: USDA NRCS Soil Data Access (SSURGO), Westchester County survey area NY119, queried at points inside Yonkers and in one sample box whose response stopped at 12 polygons, so the list is incomplete; NRCS Official Series Descriptions (Charlton 05/2016, Chatfield 04/2017); USGS State Geologic Map Compilation (Data Series 1052) via Macrostrat; NYS DEC flood project fact sheet. NRCS's units for its depth fields were not confirmed.
The housing stock in numbers: Yonkers, Westchester County and the State
The 2024 ACS 5-year estimates from the Census Bureau (survey years 2020-2024) count 85,006 housing units in Yonkers. Table B25035 puts the median year built at 1958, against 1959 for Westchester County and for New York State, and table B25034 dates 22,653 Yonkers units to 1939 or earlier. Census QuickFacts for Yonkers gives the city's owner-occupied rate for 2020-2024 as 46.2 percent; QuickFacts prints 61.8 percent for the county and 54.3 percent statewide. The City's 2000 Comprehensive Plan lists Cedar Knolls and Lawrence Park West (1920s) and Park Hill (1890s) among the early planned neighborhoods, and says that by 1977 Yonkers was virtually built-up.
Table B25024 of the same ACS 2024 5-year release shows how that stock is built: Yonkers has 21,030 one-unit detached houses, 3,656 attached ones, 7,789 in two-unit buildings and 8,913 in buildings of three or four, against 22,278 in buildings of 50 or more. Whatever the building, section 103-1 of the Code of the City of Yonkers (adopted 1911) makes repair of the sidewalk in front of a lot the duty of that lot's owner. For front steps, our concrete steps and stoops page sets out the State's riser, tread and handrail values.
| ACS 2024 5-year (table) | Yonkers | Westchester County | New York State |
|---|---|---|---|
| Housing units (B25001) | 85,006 | 394,358 | 8,585,241 |
| Owner-occupied units (B25003) | 37,737 | 230,602 | 4,196,985 |
| Owner-occupied rate (QuickFacts) | 46.2% | 61.8% | 54.3% |
| 1-unit detached (B25024) | 21,030 | 171,116 | 3,533,093 |
| 1-unit attached (B25024) | 3,656 | 25,389 | 470,247 |
| 2 units (B25024) | 7,789 | 30,270 | 822,296 |
| 3 or 4 units (B25024) | 8,913 | 27,440 | 594,096 |
| 50 or more units (B25024) | 22,278 | 68,104 | 1,435,458 |
| Built 1939 or earlier (B25034) | 22,653 | 108,495 | 2,598,944 |
| Built 1940 to 1949 (B25034) | 7,234 | 27,873 | 656,472 |
| Built 1950 to 1959 (B25034) | 15,668 | 69,262 | 1,210,607 |
| Built 1960 to 1969 (B25034) | 13,255 | 55,175 | 1,040,358 |
| Built 2020 or later (B25034) | 479 | 3,972 | 64,884 |
| Median year built (B25035) | 1958 | 1959 | 1959 |
Source: U.S. Census Bureau, American Community Survey 2024 5-year estimates (2020-2024), tables B25001, B25003, B25024, B25034 and B25035; owner-occupied rates as Census QuickFacts prints them for 2020-2024. Selected rows: the 5-to-49-unit bins and the build decades from 1970 to 2019 are in the same tables.
Sources & Methodology
Every figure above was taken from the primary sources below (accessed 2026-10-11). Where a number is derived (arithmetic on published figures) or covers a broader period or area, the text says so.
- NOAA National Centers for Environmental Information, U.S. Climate Normals 1991-2020 (annual and seasonal normals documentation) — Normals for Dobbs Ferry-Ardsley (USC00302129), Westchester County Airport in White Plains (USW00094745) and Central Park, New York City (USW00094728), read through NCEI's data service.
- City of Yonkers, Table R301.2(1), climatic and geographic design criteria (2020 RC-NYS, revision 12/28/2020) — The frost line entry is read as 3 feet 6 inches; the foot mark could not be confirmed. Harrison and Croton-on-Hudson print 42 inches in their own tables.
- New York State Department of State, Technical Bulletin TB-1009-RCNYS, Requirements for Completing Table R301.2(1) in the 2020 Residential Code of New York State
- New York State Department of State, Residential Building Plan Review handbook (9E25), based on the 2025 Residential Code of New York State
- New York State Department of State, Notice of Adoption of the 2025 Uniform Code
- Pennsylvania Housing Research Center, Penn State, Residential Concrete 101 (12/12/2016), reprinting 2009 International Residential Code Table R402.2
- National Ready Mixed Concrete Association, CIP 27, Cold Weather Concreting
- National Ready Mixed Concrete Association, CIP 12, Hot Weather Concreting
- National Ready Mixed Concrete Association, CIP 2, Scaling Concrete Surfaces
- American Concrete Institute, technical FAQ: How does the temperature influence curing? — ACI's FAQs on hot-weather limits under ACI 301-20 and ACI 305.1-14 and on freezing and thawing are cited in the text.
- USDA Natural Resources Conservation Service, Official Soil Series Description, Charlton series — Soil map units from NRCS Soil Data Access (SSURGO, Westchester County survey area NY119); bedrock units from the U.S. Geological Survey's State Geologic Map Compilation (Data Series 1052), read through Macrostrat.
- New York State Department of Environmental Conservation, Yonkers Flood Damage Reduction Project fact sheet
- U.S. Environmental Protection Agency, Stream Daylighting at Brownfield Sites (February 2021)
- U.S. Census Bureau, American Community Survey 2024 5-year estimates, table B25034 (year structure built) — Tables B25001, B25003, B25024 and B25035 for Yonkers, Westchester County and New York State come from the same release.
- U.S. Census Bureau, QuickFacts, Yonkers city, New York
- City of Yonkers, Connections: The Yonkers Comprehensive Plan (September 2000)
- Code of the City of Yonkers, Chapter 103, Streets and Sidewalks
- City of Yonkers, Department of Public Works, Snow and Ice Control (no date shown)
Send us photos and measurements of the job, and we reply with a free written quote that names the permits a Yonkers pour needs.
Quick Answers
How cold is too cold to pour concrete?
Fresh concrete is at risk once its own temperature drops below about 25 degrees F, where NRMCA's CIP 27 (1998, 2014) says it freezes; with well-planned operations, ACI notes, concrete has been placed safely well below -4 degrees F. CIP 27's cold weather is an average daily temperature below 40 degrees F for more than 3 days in a row, with the air at or below 50 degrees F for more than half of any 24-hour period. The sheet wants sections under 12 inches thick placed at 55 degrees F or warmer and protected until they gain 500 psi, about two days after placement. We do not pour on frozen ground, and in cold weather we cover new work with the blankets, tarps or enclosures CIP 27 lists.
How deep is the frost line in Westchester County?
Each local jurisdiction sets its own: the State's bulletin TB-1009-RCNYS gives New York no single statewide frost depth and has the local jurisdiction provide the minimum footing depth below finish grade, and the Westchester tables in our sources come to 42 inches, with one caveat for Yonkers. Harrison's design criteria table and Croton-on-Hudson's 2020-code table, effective 5/12/2020, both print 42 inches. The City of Yonkers' table, revised 12/28/2020, has a frost cell read in context as 3 feet 6 inches, the same depth, though its foot mark could not be confirmed. Before a footing goes in, confirm the depth with the building department of the city, village or town where the job is; in Yonkers that is the Department of Housing and Buildings.
How many freeze-thaw cycles does Yonkers get?
No published count exists in the sources behind this page: the NOAA 1991-2020 normals used here carry no freeze-thaw tally, and none of the sources gives one for Yonkers, the New York area or the Northeast. What NOAA does publish for Dobbs Ferry-Ardsley, north of the city, is 108.9 days a year whose low is 32 degrees F or less and 13.8 days whose high is also at or below freezing. A peer-reviewed study in Climatic Change (published online 29 December 2025) defines a freeze-thaw day as one with a low at or below freezing and a high above it, but gives no count for New York. ACI adds that freeze-thaw distress can be avoided by keeping concrete from becoming saturated.
Free Yonkers Quote